Maximum report processing jobs limit reached error
If this error is ever encountered:
It is due to the Print Job limit being hit. By default, it is 75. Once this value is reached, the above error will happen and IIS will need to be reset in order to get Launchpad working again.
The Job limit can be extended to a higher number by modifying the registry (Depending on system architecture, it may not be in the WOW6432Node):
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\SAP BusinessObjects\Crystal Reports for .NET Framework 4.0\Report Application Server\Server
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\SAP BusinessObjects\Crystal Reports for .NET Framework 4.0\Report Application Server\InprocServer
Change the Print Job Limit from 75 to a higher number. -1 will make it unlimited, but can cause performance issues on the server itself.
Crystal tabulates the count, and each report can and will
likely represent multiples. It is not fully clear on the exact parameters
the Crystal engine will use but reports containing sub reports start adding to
that number, among other reporting techniques.
Recommendations:
A good start point for the PrintJobLimit is 3-4X the number
of active reports.
Launchpad will display the number of active reports in
memory; This is on the footer of the main listing page. Monitoring this page thought the day, looking
for the “peak activity” is recommend
Related Articles
Launchpad - Release Notes
version: 1100.1000 Date of Release 2024.11.18 Upgrade to support Visual 11 Oracle SQL Server will not work with this Release (to be done at a later date) January 2024 Updates Visual ERP Application Integration Enhanced (Revision 23129, 22nd January ...
Launchpad Won't Export Crystal Reports
If Launchpad suddenly stops exporting reports (even though reports are still running fine), the issue may be that the TEMP directory on the server is full. Newer versions of Launchpad should automatically clean up the directory, though this can ...
Maximum Request Length Exceeded
To correct this error, edit the "Web.config" in the root directory of Launchpad and add / edit the httpRuntime node to allow bigger file sizes to be uploaded: maxRequestLength is in KB executionTimeout is in seconds
Launchpad Scheduler - Error When Editing Scheduler
Error Caused by Account Settings Id or Password If the Account id/password are not setup correctly the end user could get the following message when trying to add new tasks. To Fix this make sure the account id and password are correct. File->Task ...
Launchpad Updater 530 Not logged in Error